Schoeps MAB 1000 Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050
www.schoeps.de · [email protected]
13
English
1. OCT Front System with MAB 1000
(OCT=Optimized Cardioid Triangle by Dr.
Theile, Institut für Rundfunktechnik IRT)
Aim: the pickup of the three front chan nels
(L, C, R) of a surround recording
The preferred setup for OCT uses a forward-
facing cardioid for the center channel. For the
front L and R channels two supercardioid micro-
phones are placed at opposite ends of an
imaginary line running about 8 cm behind the
center microphone. These two microphones
should be 40 – 90 cm apart, depending on
the required recording angle*, and must face
squarely outward, away from center (see dia-
grams below and on the following pages).
Good separation between the center-to-left
sector and the center-to-right sector is obtained
with this method. For example, sound origi-
nating from half right is picked up only very
weakly by the left microphone. Sound from
the extreme right will be picked up directly
on-axis by the right-facing supercardioid (0 dB)
and by the forward-facing cardioid (attenuated
by 6 dB due to its direc tional pattern). Finally
it will be picked up, with a delay caused by the
increased distance, on the rear lobe of the left-
facing supercardioid. The polar pattern attenu-
ation for this will be 10 dB and the polarity will
be inverted. These factors prevent the forma-
tion of annoying “phantom images“ of sound
sources in the wrong sector during playback.
A clean center channel is conveyed by this
system, since front-incident sound is picked up
mainly by the cardioid in the center. Because
of their high directivity, the left and right micro-
phones pick up front-incident sound only at a
much lower level.
If the cardioid is placed 8 cm forward, the
following recording angles* will result, depend-
ing on the distance between the supercardioids:
40 cm: 160°, 50 cm: 140°,
60 cm: 120°, 70 cm: 110°,
80 cm: 100°, 90 cm: 90°,
It is better to err in the direction of greater
spacing, so that one can be sure to avoid cen-
ter-heavy images.
The fact that the supercardioids receive so
much of their sound from off axis necessitates
the use of small-diaphragm condenser micro-
phones, as only this type of microphone has
the requisite independence of frequency
response from the angle of sound incidence.
The CCM 41V and the MK 41V are particularly
well suited for this application but the CCM 41
or MK 41 can also be used.
Surround with OCT Front System
CCM 41VL or
CCM 41L
8 cm
40 – 90 cm, dependent on
the intended recording angle*
CCM 41VL or
CCM 41 L
CCM 4L
(an omni, e.g. CCM 2SL,
can be substituted)
C
L
R
1.1 OCT Front System
basic version
FRONT
* the range within which the sound sources should
be placed, as “seen“ by the microphone
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14 15 16 17

Kommentare zu diesen Handbüchern

Keine Kommentare